小说排行榜,欢乐颂小说结局是什么,盗墓笔记小说txt下载

99亚洲精品5在线观看_亚洲国产成人av无码中_在线看AV片得得的爱免费_羞羞视频直播_高潮国产激情对白视频_一区日韩国产精品_欧美日韩免费激情_亚洲高清一区二区a毛片9_草莓视频app下载_放荡的丰满少妇中文字幕

        返回上一頁

        DNP3 Master Ethernet

        產(chǎn)品概覽

        DNP3 Master Ethernet 設(shè)備驅(qū)動(dòng)提供一種簡單且可靠的方法將 DNP3 Ethernet 設(shè)備連接到您的 OPC 客戶端應(yīng)用程序,包括 HMI、SCADA、Historian、MES、ERP 和不計(jì)其數(shù)的自定義應(yīng)用程序。DNP3 Ethernet 驅(qū)動(dòng)通過身份驗(yàn)證提高安全性,并能夠管理分布式設(shè)備資產(chǎn)及其屬性。

        聯(lián)系銷售人員

        詢價(jià)或售前咨詢

        • 電話:4006 139 938 / 021-5102 8348
        • 電子郵件:

        資源

        • 性能
        • 協(xié)議
        • 支持的設(shè)備
        • 可用語言
        • 應(yīng)用程序支持
        • 發(fā)行說明
        • 相關(guān)硬件產(chǎn)品
        • 特色套件

        性能

        • DNP3 協(xié)議
        • 支持安全的身份驗(yàn)證 (SAv2)
        • 在第 3 級(jí)實(shí)施 DNP3
        • 通過 IP 尋址與多個(gè) DNP3 設(shè)備通信
        • 支持 TCP(事件、監(jiān)視和控制)- 以太網(wǎng)端口
        • 支持 UDP
        • 支持事件緩沖和回放
        • 支持設(shè)備自動(dòng)降級(jí)
        • 主動(dòng)提供消息
        • 模擬死區(qū)配置
        • 支持自動(dòng)生成標(biāo)簽
          • 通道和設(shè)備配置、身份驗(yàn)證統(tǒng)計(jì)信息、數(shù)據(jù)集、設(shè)備屬性、文件控制

        協(xié)議

        • DNP 3 (Distributed Network Protocol)

        支持的設(shè)備

        • This driver supports any DNP3 slave device.

        可用語言

        • 英語

        應(yīng)用程序支持

        • DDE Format CF_Text and AdvancedDDE
        • NIO Interface for iFIX
        • OPC .NET Service (OPC .NET) Version 1.00
        • OPC Alarms and Events (OPC AE) Version 1.10
        • OPC Data Access (OPC DA) Versions 1.0a, 2.0, 2.05a, and 3.0
        • OPC Unified Architecture (OPC UA) Version 1.02
        • SuiteLink and FastDDE for Wonderware

        發(fā)行說明

        6.1.601.0

        2017/4/4

        • Added new channel-level property for maximum Link Layer Status Request retries.

        6.0.2107.0

        2016/11/15

        • The Update Key password property is obfuscated (not displayed in plain text).

        5.20.396.0

        2016/5/3

        • Fixed an issue with Event Playback that could cause tag quality to temporarily go “Bad” despite a successful unsolicited response.

        5.18.662.0

        2015/6/23

        • The driver no longer attempts communication with the device if a client is only referencing System (internal) tags, which do not require device communication.
        • Added the ability to disable time synchronization messages.
        • Corrected an issue where a disabled device on a virtual network could block other devices from communicating.

        5.17.495.0

        2015/2/24

        • Added support for 10 ms update rates to Event Class 1, 2, and 3 polling intervals.
        • Fixed an issue where malformed packets could disrupt communications.
        • Fixed an issue where an out-of-bound read vulnerability could exhaust resources and prevent the driver from working.

        5.16.722.0

        2014/10/21

        • Updated the maximum length of the XML schema Destination Host element to 255.

        5.13.191.0

        2013/10/15

        • Added Retry Attempts for the following requests: Integrity Poll, Event Poll, Disable Unsolicited, Data Set Exchange, Automatic Tag Generation, and Explicit Reads/Writes.
        • Added the new "Max Timeouts" property (located in the Communications tab of Device Properties).
        • Fixed an issue where a Disable Unsolicited Request would not be sent when only one or two of the classes are configured with Unsolicited Messages disabled and no class is configured with Unsolicited Messages enabled.

        5.12.140.0

        2013/6/18

        • Addressed a security vulnerability that could allow a master station to be sent into an infinite loop by sending a specially crafted TCP packet or through serial communications. A successful attack exploiting this vulnerability could allow an attacker to put the master station into an infinite loop, causing a denial-of-service condition. The master station (KEPServerEX runtime service) must be manually restarted to recover from the loop condition.
        • Fixed an issue with g70v3 Open File requests, where the File Size and Time of Creation fields were not being initialized properly when the request was to open a file for writing on the slave.
        • Corrected an issue introduced through a fix in server version 5.10 in which events would continue to play back when a device was in an error state. Errors other than Device Not Responding (DNR) were not being considered. When event play back is enabled and the event poll times out while communicating, the .Value and .Timestamp tags will receive BAD quality (which was the previous behavior).
        • Fixed an issue introduced in server version 5.10 where integrity and/or event polls would not occur on schedule if channel serialization was in use with many .Explicit Tags.
        • Corrected an issue where an "Initialization Completed" message would be posted when no communications had occurred with the device.
        • Changed the Exchange Data Sets device property's default setting from True to False.
        • Added support for legacy devices that use a local time zone adjusted with time reference instead of the UTC time base in events and during time synchronization.
        • Converted the Communications device property page to a grid control.
        • Fixed an issue where processing too many continuous internal/cache tags may have delayed the processing of device tags (especially when Channel Serialization was in use and devices were not communicating).
        • Fixed an issue where a non-empty Activate Configuration Object string incorrectly triggered automatic tag generation when other device properties were modified.
        • Fixed a rare issue where an erroneous file transfer failure message could be posted along with a file transfer completed successfully message when the file transfer was successful.
        • Corrected an issue where event play back paused during TCP connection attempts.
        • Corrected an issue where event play back paused while the device was demoted.

        5.11.250.0

        2013/3/5

        • Fixed an issue where the server could become unresponsive during automatic tag generation. This problem was introduced in the 5.10 release.
        • Fixed an issue where the driver failed to report an Event Log error message if the socket bind failed. This message failure occurred for bind failures where the protocol selected was UDP and the optional source port was set to a non-zero value.
        • Added an error message to be posted when a tag fails due to the DNP flags containing an exception condition. The error message will list the actual DNP flags byte in hexadecimal format as well as a comma delimited string listing the exceptions. An example of the message is as follows: Unable to read tag '1.0.0.Explicit' on device 'Channel1.Device1'. Device indicates one or more exception conditions (DNP flags byte='0x28' - 'Offline, Remote Force, Chatter Filter').
        • Fixed an issue where on-the-fly changes to channel properties that affect the socket did not consistently force a socket reconnect.
        • Fixed an issue where no 'Device Not Responding' message was logged and tags did not show Bad quality when the keep-alive request timed out and the project was configured with no event or integrity polling and no explicit read tags.
        • Fixed an issue where tag quality was not updated after disabling the Enable Data Collection property.

        5.10.205

        2012/11/13

        • Changed the Data Link Layer Confirmation Timeout from 2 seconds to the configurable Channel Response Timeout.
        • Fixed an issue where collected events did not continue to playback when the device was in an error state.
          • Tag quality will be Bad if the device error state continues after playback completes.
          • During device demotion, tags will have Bad Quality and no playback. After the device is promoted, tag quality will be Good and playback will continue.
        • Fixed an issue where collected events were incorrectly deleted from the driver's cache after specific communication failures.
        • Resolved an issue where the Auto-Demotion settings in device properties were not used on startup.

        5.9.170

        2012/6/26

        • Added the new internal tag "_TimeSyncStyle".
        • Fixed an issue where the driver would fail to send confirmations to unsolicited responses. This occurred if the slave failed to respond to a Link Status Request, and instead sent its own Link Status Request.

        5.8.109.0

        2012/2/21

        Updated refresh logic to improve usability with projects that reference more than a hundred channels.

        5.6.122.0

        2011/7/25

        • DNP3 Enhancements for Phase-III support of WITS specification include File Control and Activate Configuration
        • Added Device Property Page to allow configuring the DNP File Control object group 70 and the DNP Activate Configuration function code 31.
        • Implemented new tag addresses to allow clients to manage file transfer and activate configuration functions:
        • Converted the Advanced device property page to a grid control.
        • On restart, Events received in the response to the initial integrity poll are no longer lost when the response did not complete within the response timeout.
        • Added an event message to report when the session has completed startup.
        • Added support for device auto-demotion.
        • Added an event message to report when an Enable Unsolicited Messaging request fails, and when an item is demoted/promoted. Added the ability to post an informational message when certain IIN bits are set in a response. Improved tag cleanup.
        • Added an event message to report when LAN Time Sync write to g50v3 is not supported.
        • To correctly open 4x-based projects, modified the XML schema transform file to check for out of range values and/or to assign defaults for the following channel and device properties: Protocol, DestinationIP, ResponseTimeoutMilliseconds, RequestTimeoutMilliseconds, UnsolicitedModeClass1, OperateMode, and EnableFeedbackPollAfterWrite.
        • Resolved an issue where items might not clean up properly when a client disconnected from the server if the items were in a bad quality state due to an non-responsive RTU.

             • 70.<file index>.LocalFileName (on Master station)

             • 70.<file index>.RemoteFileName (on RTU)

             • 70.<file index>.Download

             • 70.<file index>.Upload

             • ActivateConfig

        5.5.94.0

        2011/2/18

        • Added support for writing to Device Attributes (Object Group 0). This feature is required to meet the DNP WITS standard.
        • Added support for writing to Data Sets (Object Group 87). This feature is required to meet the DNP WITS standard.
        • The driver now supports the ability to play back Data Set snapshot data.
        • New settings were added to the Device Properties page that allow for users to ignore forced flags when setting quality.
        • Fixed issues with loading legacy server (.xml) project files.
        • Fixed an issue where the first buffered event after startup was never displayed when the Playback Rate was shorter than the tag's Update Rate.
        • A "Device Not Responding" message will no longer be reported in certain situations where the device was actually communicating.
        • Added Event Log error messages for cases of incomplete or invalid responses or invalid authentication.
        • Fixed an issue where the driver was reporting "Failed to initialize communication stack" in situations where serialization was enabled.
        • Improved channel management when communication errors are encountered during startup.
        • Fixed an issue where data set CTLS and CTLV element types were shown as having bad quality.
        • Fixed an issue where Communication Serialization and Aggressive Mode Authentication were enabled.
        • Added informational message to report the number of data set tags per data set added during auto tag generation.

        5.4.131.0

        2010/10/28

        • Added Keep-Alive Interval device property to the Communication page as well as an Event Log message to warn the user if loading an XML project discovers a Keep-Alive interval configured for a UDP channel.
        • Enhancements for Phase I support of WITS specification include the following.

        Device Attribute - Object Group 0:

             • Standard Attributes at Index 0 (such as Vendor Name, Product Name, Site Name, Software Version, Hardware

        Version, Configuration File Names, and Configuration File Version) Version, Configuration File Names, and Configuration File Version)

             • User Defined Attributes for Index 1 and above.

             • Read Only.

        Secure Authentication - Object Group 120:

             • Challenge - Response.

             • Pre-shared Update Keys.

             • Aggressive Mode.

             • Session Keys - bidirectional.

             • Security Statistics.

        Data Sets - Object Groups 85, 86, 87, and 88:

             • Prototypes.

             • Descriptors.

             • Event and Static conditions.

             • Outstation defined data sets.

             • Read Only.

        • Added an error message for the situation in which a device's Slave address is a duplicate of another device's Master or Slave address.
        • Added an error message for the situation in which a device contains the same Master and Slave address.
        • Added the following internal tags:
        • Updated the driver to release items more quickly for unresponsive devices, following client disconnect.

             • _Protocol

             • _DestinationHost

             • _DestinationPort

             • _SourcePort

             • _ChannelResponseTimeout

             • _IntegrityPollInterval

             • _EventClass1PollInterval

             • _EventClass2PollInterval

             • _EventClass3PollInterval

             • _DeviceRequestTimeout

        5.3.118.0

        2010/6/9

        • Initial release of DNP drivers in 5x.

        相關(guān)硬件產(chǎn)品

        工業(yè)以太網(wǎng)交換機(jī)

        特色套件

        什么是驅(qū)動(dòng)?

        KEPServerEX 不僅是 OPC 服務(wù)器,它還是一種適用于工業(yè)自動(dòng)化和 IoT 的連接平臺(tái)。只需下載 KEPServerEX,然后從包含 150 多種設(shè)備驅(qū)動(dòng)、客戶端驅(qū)動(dòng)和高級(jí)插件的 Kepware 庫中選擇,以便適合您工業(yè)控制系統(tǒng)的獨(dú)特通信要求。

        驅(qū)動(dòng)是一種軟件組件,能夠使 KEPServerEX 滿足某個(gè)特定設(shè)備、系統(tǒng)或其他數(shù)據(jù)源的連接要求。此驅(qū)動(dòng)處理 KEPServerEX 與數(shù)據(jù)源進(jìn)行的所有專屬通信;客戶端接口處理通向監(jiān)控或控制設(shè)備的應(yīng)用程序的所有連接,包括支持的 OPC 連接、專屬連接和開放式標(biāo)準(zhǔn)連接。

        驅(qū)動(dòng)可以單獨(dú)或以套件形式獲得授權(quán)許可。隨著連接需求的發(fā)展,可以按需對(duì)其他驅(qū)動(dòng)進(jìn)行許可。

        上海泗博自動(dòng)化技術(shù)有限公司  Copyright(c) 2005-2021   SiboTech.net All Rights Reserved 
        foot
        公司總機(jī): 021-6482 6558    |   滬ICP備15057390號(hào)